Docs Self-Managed Manage Cluster Maintenance Cluster Diagnostics This is documentation for Self-Managed v24.2. To view the latest available version of the docs, see v24.3. Cluster Diagnostics This topic provides guides for using tools and tests to help diagnose and debug a Redpanda cluster. Disk and network self-test benchmarks When anomalous behavior arises in a cluster and you’re trying to figure out whether it’s caused by faulty hardware (disks, NICs) of a cluster’s machines, run rpk cluster self-test (self-test) to characterize their performance and compare it with their expected, vendor-specified performance. Self-test runs a set of benchmarks to determine the maximum performance of a machine’s disks and network connections. For disks, it runs throughput and latency tests by performing concurrent sequential operations. For networks, it selects unique pairs of Redpanda nodes as client/server pairs, then it runs throughput tests between them. Self-test runs each benchmark for a configurable duration, and it returns IOPS, throughput, and latency metrics. Cloud storage tests If you use Tiered Storage, run self-test to verify that you have configured your cloud storage accounts correctly. Self-test performs the following tests to validate cloud storage configuration: Upload an object (a random buffer of 1024 bytes) to the cloud storage bucket/container. List objects in the bucket/container. Download the uploaded object from the bucket/container. Download the uploaded object’s metadata from the bucket/container. Delete the uploaded object from the bucket/container. Upload and then delete multiple objects (random buffers) at once from the bucket/container. See the rpk cluster self-test start reference for cloud storage test details. Self-test command examples Start self-test To begin using self-test, run the self-test start command. rpk cluster self-test start For command help, run rpk cluster self-test start -h. For additional command flags, see the rpk cluster self-test start reference. Before it starts, self-test start asks for your confirmation to run its potentially large workload. Example start output: ? Redpanda self-test will run benchmarks of disk and network hardware that will consume significant system resources. Do not start self-test if large workloads are already running on the system. (Y/n) Redpanda self-test has started, test identifier: "031be460-246b-46af-98f2-5fc16f03aed3", To check the status run: rpk cluster self-test status The self-test start command returns immediately, and self-test runs its benchmarks asynchronously. Check self-test status To check on the status of self-test, run the self-test status command. rpk cluster self-test status For command help, run rpk cluster self-test status -h. For additional command flags, see the rpk cluster self-test status reference. If benchmarks are currently running, self-test status returns a test-in-progress message. Example status output: $ rpk cluster self-test status Nodes [0 1 2] are still running jobs To automate checking the status of self-test, the status command can output its results in JSON format by using the --format=json option: rpk cluster self-test status --format=json If benchmarks have completed, self-test status returns their results. Test results are grouped by broker ID. Each test returns the following: Name: Description of the test. Info: Details about the test run attached by Redpanda. Type: Either disk, network, or cloud test. Test Id: Unique identifier given to jobs of a run. All IDs in a test should match. If they don’t match, then newer and/or older test results have been included erroneously. Timeouts: Number of timeouts incurred during the test. Start time: Time that the test started, in UTC. End time: Time that the test ended, in UTC. Avg Duration: Duration of the test. IOPS: Number of operations per second. For disk, it’s seastar::dma_read and seastar::dma_write. For network, it’s rpc.send(). Throughput: For disk, throughput rate is in bytes per second. For network, throughput rate is in bits per second. Note that GiB vs. Gib is the correct notation displayed by the UI. Latency: 50th, 90th, etc. percentiles of operation latency, reported in microseconds (μs). Represented as P50, P90, P99, P999, and MAX respectively. If Tiered Storage is not enabled, then cloud storage tests do not run, and a warning displays: "Cloud storage is not enabled." All results are shown as 0. Example status output: test results $ rpk cluster self-test status NODE ID: 0 | STATUS: IDLE ========================= NAME 512KB sequential r/w INFO write run (iodepth: 4, dsync: true) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:02:45 UTC 2024 END TIME Fri Jul 19 15:03:15 UTC 2024 AVG DURATION 30002ms IOPS 1182 req/sec THROUGHPUT 591.4MiB/sec LATENCY P50 P90 P99 P999 MAX 3199us 3839us 9727us 12799us 21503us NAME 512KB sequential r/w INFO read run TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:03:15 UTC 2024 END TIME Fri Jul 19 15:03:45 UTC 2024 AVG DURATION 30000ms IOPS 6652 req/sec THROUGHPUT 3.248GiB/sec LATENCY P50 P90 P99 P999 MAX 607us 671us 831us 991us 2431us NAME 4KB sequential r/w, low io depth INFO write run (iodepth: 1, dsync: true) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:03:45 UTC 2024 END TIME Fri Jul 19 15:04:15 UTC 2024 AVG DURATION 30000ms IOPS 406 req/sec THROUGHPUT 1.59MiB/sec LATENCY P50 P90 P99 P999 MAX 2431us 2559us 2815us 5887us 9215us NAME 4KB sequential r/w, low io depth INFO read run TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:04:15 UTC 2024 END TIME Fri Jul 19 15:04:45 UTC 2024 AVG DURATION 30000ms IOPS 430131 req/sec THROUGHPUT 1.641GiB/sec LATENCY P50 P90 P99 P999 MAX 1us 2us 12us 28us 511us NAME 4KB sequential write, medium io depth INFO write run (iodepth: 8, dsync: true) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:04:45 UTC 2024 END TIME Fri Jul 19 15:05:15 UTC 2024 AVG DURATION 30013ms IOPS 513 req/sec THROUGHPUT 2.004MiB/sec LATENCY P50 P90 P99 P999 MAX 15871us 16383us 21503us 32767us 40959us NAME 4KB sequential write, high io depth INFO write run (iodepth: 64, dsync: true) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:05:15 UTC 2024 END TIME Fri Jul 19 15:05:45 UTC 2024 AVG DURATION 30114ms IOPS 550 req/sec THROUGHPUT 2.151MiB/sec LATENCY P50 P90 P99 P999 MAX 118783us 118783us 147455us 180223us 180223us NAME 4KB sequential write, very high io depth INFO write run (iodepth: 256, dsync: true) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:05:45 UTC 2024 END TIME Fri Jul 19 15:06:16 UTC 2024 AVG DURATION 30460ms IOPS 558 req/sec THROUGHPUT 2.183MiB/sec LATENCY P50 P90 P99 P999 MAX 475135us 491519us 507903us 524287us 524287us NAME 4KB sequential write, no dsync INFO write run (iodepth: 64, dsync: false) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:06:16 UTC 2024 END TIME Fri Jul 19 15:06:46 UTC 2024 AVG DURATION 30000ms IOPS 424997 req/sec THROUGHPUT 1.621GiB/sec LATENCY P50 P90 P99 P999 MAX 135us 183us 303us 543us 9727us NAME 16KB sequential r/w, high io depth INFO write run (iodepth: 64, dsync: false) TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:06:46 UTC 2024 END TIME Fri Jul 19 15:07:16 UTC 2024 AVG DURATION 30000ms IOPS 103047 req/sec THROUGHPUT 1.572GiB/sec LATENCY P50 P90 P99 P999 MAX 511us 1087us 1343us 1471us 15871us NAME 16KB sequential r/w, high io depth INFO read run TYPE disk TEST ID 21c5a3de-c75b-480c-8a3d-0cbb63228cb1 TIMEOUTS 0 START TIME Fri Jul 19 15:07:16 UTC 2024 END TIME Fri Jul 19 15:07:46 UTC 2024 AVG DURATION 30000ms IOPS 193966 req/sec THROUGHPUT 2.96GiB/sec LATENCY P50 P90 P99 P999 MAX 319us 383us 735us 1023us 6399us NAME 8K Network Throughput Test INFO Test performed against node: 1 TYPE network TEST ID 5e4052f3-b828-4c0d-8fd0-b34ff0b6c35d TIMEOUTS 0 DURATION 5000ms IOPS 61612 req/sec THROUGHPUT 3.76Gib/sec LATENCY P50 P90 P99 P999 MAX 159us 207us 303us 431us 1151us NAME 8K Network Throughput Test INFO Test performed against node: 2 TYPE network TEST ID 5e4052f3-b828-4c0d-8fd0-b34ff0b6c35d TIMEOUTS 0 DURATION 5000ms IOPS 60306 req/sec THROUGHPUT 3.68Gib/sec LATENCY P50 P90 P99 P999 MAX 159us 215us 351us 495us 11263us NAME Cloud Storage Test INFO Put TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 8ms NAME Cloud Storage Test INFO List TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 1ms NAME Cloud Storage Test INFO Get TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 1ms NAME Cloud Storage Test INFO Head TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 0ms NAME Cloud Storage Test INFO Delete TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 1ms NAME Cloud Storage Test INFO Plural Delete TYPE cloud TEST ID a349685a-ee49-4141-8390-c302975db3a5 TIMEOUTS 0 START TIME Tue Jul 16 18:06:30 UTC 2024 END TIME Tue Jul 16 18:06:30 UTC 2024 AVG DURATION 47ms If self-test returns write results that are unexpectedly and significantly lower than read results, it may be because the Redpanda rpk client hardcodes the DSync option to true. When DSync is enabled, files are opened with the O_DSYNC flag set, and this represents the actual setting that Redpanda uses when it writes to disk. Stop self-test To stop a running self-test, run the self-test stop command. rpk cluster self-test stop Example stop output: $ rpk cluster self-test stop All self-test jobs have been stopped For command help, run rpk cluster self-test stop -h. For additional command flags, see the rpk cluster self-test stop reference. For more details about self-test, including command flags, see rpk cluster self-test. Back to top × Simple online edits For simple changes, such as fixing a typo, you can edit the content directly on GitHub. Edit on GitHub Or, open an issue to let us know about something that you want us to change. Open an issue Contribution guide For extensive content updates, or if you prefer to work locally, read our contribution guide . Was this helpful? thumb_up thumb_down group Ask in the community mail Share your feedback group_add Make a contribution Configure Availability Forced Partition Recovery